SABS Test Report

Fire Resistance Test Report

Report on the fire properties from FIRELAB cc (13 March, 2009 Contract No. FTC09-001). The overall classification of B/B1/B2 is applicable to this product in terms of the SANS 428 Specification.

The Fire Retardant Burnt the sample with spirit Iamb flame for 3 seconds, the panel burn, but the sample extinguished once away from the flame.

Deflection after 60°C The PVC board was placed on the metals tray, and then put into the air-circulating over of 60°C, the sample was placed in the oven for 10min. The sample qualifies below 6% of board width.

Deflection after -20°C The PVC board was placed on the metals tray, and then put into the cold chamber of -20°C, kept in the temperature for 10min. The sample qualifies below 5% of board width.